Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of US$ 2/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
We support OEM /ODM, the breaking capacity have 4.5KA,6KA,10KA and so on, tell us what you want, we can produce it!
Key Words: MCB; Miniature circuit breakers
Key Parameters:
· CE/CB/ISO9001/CCC certificates;
· Rated voltage:230/400VAC;
· frequency50/60Hz;
· Rated current:6,10,16,20,25,32,40,50,63A;
· 1/2/3/4poles optional;
· Mechniacal life:10,000times;
· Flame-redardant:PA66 nylon material;
· Protection degree:IP20;
· With over load/short circuit protection;
· Standard:IEC60898;GB10963.1
· Enduring tem.55°C
· Breaking Capacity:4/6KA;
· Lighting/Motor protection optional
Application:
DZ47-63 high breaking miniature circuit breaker has the features of structure advanced, performance reliable, breaking capacity high, appearance elegant and its shell and parts are made of material with impact resistance, strong flame-retardant feature.
It is suitable to power system of 50or 60 frequency ,Ue 400V and below, Ui 63A and below.
It is mainly applied at office building, residence, for lighting , power distribution and overload and short circuit protection of equipment. Normally, it also can be used as the not frequent transfer of power system. It conforms to the standards IEC60898and GB10963.1.
Technical Parameters:
Rated voltage(V) | Poles | Rated current(A) | Rated short circuit breaking capacity | |
Test breaking capacity(KA) | Power factor | |||
230 | 1 | 6,10,16,20, 25,32,40 |
6 | 0.65~0.70 |
400 | 2,3,4 | 6 | ||
230 | 1,2 | 50,63 | 4 | 0.75~0.80 |
400 | 2,3,4 | 4 |
Test current (A) |
Rated current (A) |
Requested time | Result | Start station | Remark |
1.13In | all | t>=1h | Don't trip | Cool | |
1.45In | All | T<1h | trip | heat | Current ascends the requested value stably in 5s |
2.55In | In<=32A | 1s<t<60s | trip | Cool | Auxiliary switch closed, power is on |
2.55In | In>32A | 1s<t<120s | trip | Cool | Auxiliary switch closed, power is on |
5In(Cmode) | All | t>=0.1s | Don't trip | Cool | Auxiliary switch closed, power is on |
10In(Cmode) | All | T<0.1s | trip | Cool | Auxiliary switch closed, power is on |
10(Dmode) | All | t>=0.1s | Don't trip | Cool | Auxiliary switch closed, power is on |
14In(Dmode) | All | T<0.1s | trip | Cool | Auxiliary switch closed, power is on |